[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-fire-law-034":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-消防法規概要-034","fire-106-1-fire-law-034",106,1,34,"各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理檢修，並於檢修完成後幾日內，向當地消防機關申報？",{"A":16,"B":17,"C":18,"D":19},"10","15","20","30","B",null,[],false,"本題考點：消防安全設備定期檢修完成後，向當地消防機關申報之法定期限日數。\n【正解理由】依《消防法》第 9 條及《消防法施行細則》關於檢修申報之規定，各類場所之管理權人應委託消防安全設備檢修專業機構，或《消防法》第 7 條所定之消防設備師、消防設備士辦理檢修，並於檢修完成後十五日內，將檢修結果依規定格式向當地消防機關申報；此一日數係為使檢修結果保持時效性，避免報告書內容與現場狀況脫節，故選 B。\n【逐項排除】\n(A) 10 日錯誤。十日是若干行政程序常見的陳報期間，但檢修申報之法定期限並非十日，屬於典型的近似數字誘答。\n(B) 15 日正確。檢修完成後十五日內申報，為檢修申報制度的核心期限，亦是檢修申報書受理與逾期舉發認定的起算基準。\n(C) 20 日錯誤。條文並無二十日之申報期間，此數字在消防法規中多見於其他行政通知，不適用於檢修申報。\n(D) 30 日錯誤。三十日常見於改善期限、限期改善通知等場合，與檢修結果申報的期限性質不同，不可混用。\n【記憶點】檢修做完「半個月內」要申報——十五日是消防安全設備檢修申報的唯一法定日數。","檢修申報制度的設計邏輯，是把消防安全設備的日常維護責任明確歸屬於場所管理權人，再由具專業資格者執行技術判斷，最後以申報作為行政機關的監督接口。《消防法》第 9 條要求管理權人「應定期檢修」並「將檢修結果報請消防機關備查」,檢修頻率則依場所類別區分：供公眾使用建築物與部分高危險場所，外觀、性能檢查與綜合檢查的期程較密；一般場所則以較長週期辦理。申報期限訂為檢修完成後十五日，是在「留給業者彙整報告書的合理時間」與「維持結果時效」之間取平衡——若期限過長，報告內容與現場狀況可能已經改變，備查將失去意義。\n\n數值記憶上，消防法規中的期間可整理成一組對照：檢修完成後申報為十五日；限期改善多以三十日為常見上限；各類申請案件的補正期間則另依行政程序規定。把「十五日＝申報」單獨釘住，其餘三十日類的數字歸為「改善、補正」一族，便不易在選擇題中被相近數字帶走。\n\n易混淆概念有二：其一，檢修申報與竣工查驗不同。竣工查驗是新設或變更設備後的「上線前把關」,由審查、測試、查驗程序完成；檢修申報則是設備已上線後的「定期健檢」,兩者的申請人、文件與期限體系各自獨立。其二，委託對象有兩種法定選擇：一是檢修專業機構，二是《消防法》第 7 條所定之消防設備師、消防設備士；管理權人擇一委託即可，但責任主體始終是管理權人本人，不因委託而移轉，這也是命題常設的陷阱——把「檢修人員應申報」寫成正確敘述即屬錯誤，法定申報義務人是管理權人。\n\n相關考點延伸：同一條文群常與檢修結果不實之處罰、未依限申報之裁罰、檢修專業機構之管理辦法合併命題;《各類場所消防安全設備檢修及申報作業基準》另就報告書格式、外觀檢查與性能檢查項目有細部規定，亦是行政函釋題的高頻出處。作答時只要記住「義務人＝管理權人、期限＝十五日、對象＝當地消防機關」,即可涵蓋此類題型的多數變化。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-fire-law-033","建築物在五樓以上，且總樓地板面積在 3,000 平方公尺以上者，其火警自動警報設備鳴動方式之規定敘述，何者錯誤？",33,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-fire-law-035","下列有關建築物消防安全設備竣工查驗程序規定之敘述，何者錯誤？",35,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-fire-law-032","水霧滅火設備水源，應連結加壓送水裝置。其用於防護電氣設備者，出水壓力達每平方公分多少公斤以上？",32,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-fire-law-036","下列有關各類場所消防安全設備檢修及申報作業基準行政函釋之敘述，何者錯誤？",36,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-fire-law-031","下列有關消防法施行細則第 15 條自衛消防編組規定之敘述，何者正確？",31,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-fire-law-037","下列有關消防幫浦之性能規定之敘述，何者正確？",37,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-034",114,"依消防法施行細則規定，下列何者非屬消防防災計畫應包括事項？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-034",113,"有關防火牆及防火水幕設置基準規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-112-1-fire-law-034",112,"避難器具支固器具以直接裝置在建築物主要構造部之施工方法，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-111-1-fire-law-034",111,"依消防安全設備及必要檢修項目檢修基準規定，對二氧化碳滅火器進行重量檢查時，如失重超過多少比例以上或壓力表示值在綠色範圍外時，應予以更新，下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-110-1-fire-law-034",110,"依消防安全設備及必要檢修項目檢修基準規定，室內消防栓設備水帶製造年份超過 10 年應使用耐水壓試驗機，施以 X kgf\u002Fcm2 以上水壓試驗 Y 分鐘合格，始得繼續使用。X＋Y 為多少？",1785129970924]