[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-106-1-fire-law-004":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":51,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-消防法規概要-004","fire-106-1-fire-law-004",106,1,4,"依各類場所消防安全設備設置標準規定，幼兒園按用途分類係屬於何種場所？",{"A":16,"B":17,"C":18,"D":19},"甲類場所","乙類場所","丙類場所","丁類場所","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第十二條的場所用途分類，考的是幼兒園被歸在甲、乙、丙、丁哪一類。\n【正解理由】依《各類場所消防安全設備設置標準》第十二條，場所依用途分為甲、乙、丙、丁、戊五類。該條第二款(乙類場所)明列學校教室、幼兒園、補習班、訓練班、兒童課後照顧服務中心等教育及文教類用途；幼兒園以學齡前兒童之教保服務為主要機能，屬教育文教性質而非消費娛樂性質，分類上歸入乙類場所。故選 B。\n【逐項排除】\n(A) 甲類場所指供公眾消費、娛樂、住宿之高危險用途，如電影院、視聽歌唱場所、酒家、餐廳、旅館、醫院、長期照顧機構等，特徵是不特定多數人聚集且避難能力受限，幼兒園不在其列。\n(B) 正確。乙類場所涵蓋學校、幼兒園、補習班、圖書館、博物館、寺廟教堂等教育文化用途，幼兒園逐字列於其中。\n(C) 丙類場所指電信機器室、辦公室、金融機構、車站、飛機場大廈等業務性用途，與教保服務無涉。\n(D) 丁類場所指製造、儲存、處理性質之工廠、倉庫、汽車修理廠等，危險性來自可燃物與作業行為，與幼兒園用途完全不同。\n【記憶點】甲消費娛樂、乙教育文化、丙辦公業務、丁工廠倉儲。","第十二條是《各類場所消防安全設備設置標準》的總樞紐，後面幾乎每一種設備的設置門檻都以「甲類、乙類…」加樓地板面積或收容人員來寫，因此分類錯一次，連帶後續所有設備判斷全錯，命題頻率極高。分類的內在邏輯是「用途危險度」:甲類是不特定多數人、常在夜間或昏暗環境使用、或收容避難弱者的場所，危險度最高，設備門檻最低(面積很小就要設);乙類是特定多數人使用、有管理者在場、平時有編組演練的教育文化用途；丙類為業務用途，使用者熟悉環境；丁類則以物品危險性為主，人員密度低。\n幼兒園之所以歸乙類而非甲類，常被考生直覺推翻——因為幼兒屬避難弱者，直覺會想「應該是甲類」。但立法上把避難弱者的收容機構(如長期照顧機構、身心障礙福利機構、護理之家)放在甲類，是因其收容人員多為臥床或行動不便、需他人搬運避難；幼兒園之幼兒雖年幼，仍具自行步行避難能力且有教保人員帶領，故與學校同列乙類。這條界線正是命題者反覆測試的重點。\n值得一併記住的沿革是：我國幼托整合後，原「托兒所」與「幼稚園」於一〇一年整併為「幼兒園」,設置標準條文用語亦隨之更新；其後歷次修正並陸續強化幼兒園、兒童課後照顧服務中心等場所之火警自動警報設備與避難逃生設備要求。應考時可用口訣「甲玩、乙學、丙上班、丁做工」快速定位，再記住兩個例外方向：避難弱者收容機構往甲類靠、複合用途場所依《設置標準》第十三條另以各該用途分別認定。延伸考點則是分類確定後接著要判斷的收容人員計算方式，不同用途採用的計算基準(座位數、樓地板面積除以定值、從業人員數)並不相同，分類與收容人員兩者常在同一題中連環出現。",true,[28,32,36,40,44,47],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-fire-law-003","下列有關公共危險物品及可燃性高壓氣體設置標準暨安全管理辦法之相關用語定義，何者正確？",3,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-fire-law-005","依各類場所消防安全設備設置標準規定，下列何種場所應設置連結送水管？",5,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-fire-law-002","依據消防法規定，下列何者應舉辦防火教育及宣導？",2,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-fire-law-006","依據各類場所消防安全設備設置標準規定，集會堂使用之舞臺在設置自動撒水設備時，應選擇下列何者？",6,{"webId":45,"stem":46,"number":12,"year":11,"session":12},"fire-106-1-fire-law-001","依規定應設置消防安全設備之場所，其管理權人應委託消防設備師或消防設備士定期檢修消防安全設備，其檢修方式中之綜合檢查係指下列何者？",{"webId":48,"stem":49,"number":50,"year":11,"session":12},"fire-106-1-fire-law-007","依據各類場所消防安全設備設置標準規定，公共危險物品製造場所符合下列何者要件，則屬顯著滅火困難場所？",7,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-114-1-fire-law-004",114,"達管制量之公共危險物品及可燃性高壓氣體製造場所，其位置、構造、設備未符合公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，處其管理權人之罰鍰為何？",{"webId":57,"year":58,"stem":59,"number":13},"fire-113-1-fire-law-004",113,"有關二氧化碳滅火設備各種標示規格，下列何者錯誤？",{"webId":61,"year":62,"stem":63,"number":13},"fire-112-1-fire-law-004",112,"水霧滅火設備之放射區域在二區域以上時，其水源容量應保持 X 立方公尺以上；消防幫浦每分鐘出水量應為 Y 公升以上，下列敘述何者正確？",{"webId":65,"year":66,"stem":67,"number":13},"fire-111-1-fire-law-004",111,"國內建築型態日益多元，使災害預防及搶救複雜程度增加，下列內容何者非防災中心服勤人員訓練要點之規定？",{"webId":69,"year":70,"stem":71,"number":13},"fire-110-1-fire-law-004",110,"某 KTV 之管理權人未依規定維護該場所之消防安全設備，導致火災發生時，消防安全設備無法發揮正常功能，而造成二名消費者死亡，依消防法之規定，對管理權人之處分，下列敘述何者正確？",1785129970728]