[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-032":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-032","fire-106-1-alarm-evacuation-032",106,1,32,"針對瓦斯漏氣火警自動警報設備進行性能檢查，使用噪音計進行瓦斯漏氣檢知區域警報裝置之音量檢測時，距離警報裝置 1 公尺處，其音壓量應在多少分貝以上方為合格？",{"A":16,"B":17,"C":18,"D":19},"50","60","70","85","C",null,[],false,"本題考點：瓦斯漏氣檢知區域警報裝置之音壓判定基準，規定於《各類場所消防安全設備設置標準》第 141 條。\n【正解理由】依《各類場所消防安全設備設置標準》第 141 條，瓦斯漏氣之檢知區域警報裝置，其音壓在距離一公尺處應在 70 分貝以上；檢修即依此以噪音計於距警報裝置 1 公尺處實測，達 70 分貝以上判定合格。其用意在使警報聲明顯高於廚房、機房之背景噪音，故選 C。\n【逐項排除】\n(A) 50 分貝約為室內談話下限，低於法定判定值，無法穿透排油煙機等背景噪音。\n(B) 60 分貝仍未達本設備判定基準，以此驗收會使音壓不足之警報裝置被誤判合格。\n(C) 正確,70 分貝即距離 1 公尺處之音壓下限，為本設備之判定值。\n(D) 85 分貝屬緊急廣播設備 L 級揚聲器等更高音壓的量級，非本裝置之判定值。\n【演算步驟】判定式：實測音壓 L₁ ≥ 70 dB(距離 d = 1 m)。若改於 d = 2 m 量測，點音源衰減 ΔL = 20 log(2 m \u002F 1 m) = 20 × 0.301 = 6.02 dB;換算 L₁ = L₂ + 6.02 dB。設 2 m 處測得 66 dB,則 L₁ = 66 dB + 6.02 dB = 72.0 dB ≥ 70 dB,合格。\n【記憶點】一公尺、七十分貝，瓦斯漏氣區域警報就記這一組數。","《各類場所消防安全設備設置標準》第 141 條規範瓦斯漏氣火警自動警報設備之警報裝置，內容包含瓦斯漏氣表示燈、檢知區域警報裝置與音響警報裝置三類。檢知區域警報裝置的任務是讓「發生洩漏的那一區」的人立即知道，因此規定其音壓在距一公尺處達 70 分貝以上；若一警報裝置有效範圍內任一點至該裝置之水平距離超過規定，則須增設。表示燈則規定其亮燈在前方三公尺處能明確識別。\n分貝是對數尺度，這是本題延伸計算的關鍵。聲壓級 L = 20 log(p\u002Fp₀),參考聲壓 p₀ = 20 μPa。距離加倍時，點音源的聲壓減半，故聲壓級下降 20 log 2 ≈ 6 分貝，此即「距離加倍衰減 6 分貝」法則；能量觀點下聲強與距離平方成反比,10 log 4 同樣得 6 分貝，兩種算法一致。此外分貝不可直接相加：兩個等音壓聲源疊加只增加 10 log 2 ≈ 3 分貝，而非兩倍數值，考題常以此設計陷阱。\n音壓數值對照表便於整批記憶：瓦斯漏氣檢知區域警報裝置 1 公尺處 70 分貝以上；火警自動警報設備之火警警鈴音響在 1 公尺處 90 分貝以上；緊急廣播設備揚聲器 L 級 92 分貝以上、M 級 87 分貝以上、S 級 84 分貝以上，且 L 級適用樓地板面積超過 100 平方公尺之廣播區域。可歸納為「瓦斯 70、警鈴 90、廣播 84\u002F87\u002F92」。\n檢修實務面的判定要點：量測應在背景噪音較低的時段進行，噪音計採 A 加權；若背景噪音與警報聲差距不足 10 分貝，須就背景噪音作修正後再判定。相關考點連結尚有瓦斯漏氣受信總機自檢知器動作至警報發出應在 60 秒以內，以及緊急電源之有效動作時間要求，常與本題同卷出現。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-031","在某飯店檢查瓦斯漏氣火警自動警報設備，進行檢知器之性能檢查時，發現同一個檢知回路上裝設有 18 個瓦斯漏氣檢知器，至少應選取多少個進行試驗？",31,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-033","針對某百貨公司美食街進行檢修，下列何項試驗必須使用加瓦斯試驗器，使兩個回路之任一檢知器（各回路一個）同時動作，以確認其性能是否異常？",33,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-alarm-evacuation-030","在某飯店檢查瓦斯漏氣火警自動警報設備時，何項試驗必須切換成緊急電源之狀態？",30,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-alarm-evacuation-034","在裝設定溫式感知線型探測器場所，進行回路合成阻抗試驗時，會使用下列何種檢查儀器？",34,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-alarm-evacuation-029","瓦斯濃度達到警報濃度值後，其濃度仍繼續存在，即發出警報，但瓦斯洩漏濃度越高，則警報延遲動作時間越短，此種檢知瓦斯之警報發出方式稱作何種型式？",29,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-alarm-evacuation-035","執行檢修時，在室溫 15℃狀態下，使用加熱試驗器進行差動式局限型第二種探測器之性能檢查時，其動作時間應在多少秒內方為正常？",35,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-032",113,"依據消防安全設備及必要檢修項目檢修基準，針對瓦斯漏氣火警自動警報設備實施綜合檢查，其中切換成預備電源之狀態，使任一檢知器動作，確認其性能是否正常。此為下列何種檢查項目？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-032",112,"依消防機關受理消防安全設備檢修申報及複查注意事項複查作業中專業性複查，依消防安全設備及必要檢修項目檢修基準視轄區狀況，進行重點抽測，其必要抽測項目下列何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-032",111,"某場所進行緊急廣播設備綜合檢查，使用噪音計（A 特性）量測揚聲器之音壓位準，在距 L 級揚聲器 1 公尺處，音壓位準值應在 X dB 以上；又挑高空間採性能設計之指向型揚聲器，於廣播區域內任一位置距樓地板面 Y 公尺處，音壓位準值應在 Z dB 以上。則 X、Y、Z 值，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-032",110,"下列有關得免設緊急照明設備之處所，何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-032",109,"有關無線電通信輔助設備保護箱標示之外觀檢查的判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",1785129965540]