[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-027":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-027","fire-106-1-alarm-evacuation-027",106,1,27,"避難方向指示燈設於樓梯或坡道者，在樓梯級面或坡道表面之照度，應在多少勒克司（lx）以上？",{"A":16,"B":17,"C":18,"D":19},"1.0 勒克司（lx）","2.0 勒克司（lx）","3.0 勒克司（lx）","5.0 勒克司（lx）","A",null,[],false,"本題考點：避難方向指示燈設於樓梯或坡道時之表面照度基準，規定於《各類場所消防安全設備設置標準》有關標示設備之條文(第 146 條之 5)。\n【正解理由】依《各類場所消防安全設備設置標準》第 146 條之 5,出口標示燈及避難方向指示燈，其表示面應具一定亮度；而避難方向指示燈設於樓梯或坡道者，依同條規定，在樓梯級面或坡道表面須能達到 1 勒克司以上之照度。此處量測的是燈具投射到踏面的照度，目的在於使避難者於停電時仍能看清每一級樓梯的邊緣，避免踏空跌倒，故其標準值訂為 1.0 勒克司，故選 A。\n【逐項排除】\n(A) 正確,1.0 勒克司即樓梯級面或坡道表面之照度下限，亦與緊急照明設備在地面水平面之基準值相呼應。\n(B) 2.0 勒克司高於法定下限，並非本條所訂之判定值，以此驗收會誤判合格設備為不足。\n(C) 3.0 勒克司屬一般室內作業照明的量級，遠高於避難引導所需，法條並未如此要求。\n(D) 5.0 勒克司更高，係辦公或閱讀環境的照度概念，與停電時僅需辨識踏面輪廓的設計目的不符。\n【記憶點】樓梯級面照度看一個數字就好——1 勒克司，踏得到就夠，不是要照亮整間房。","避難方向指示燈屬《各類場所消防安全設備設置標準》所稱之標示設備，與出口標示燈同章規範。第 146 條之 5處理的是「有效範圍」與「照度」兩件事：一是指示燈依其等級(A 級、B 級、C 級)有不同的有效範圍公尺數；二是設於樓梯或坡道者，因避難者的視線落在腳下而非牆面，故改以樓梯級面或坡道表面之照度作為判定，標準為 1 勒克司以上。\n這個 1 勒克司並非憑空而來。緊急照明設備在《設置標準》中亦以地面水平面照度為判定：一般場所在 1 勒克司以上(採用日光燈或 LED 等高效光源時另有較嚴之數值要求),兩者取同一量級，是因為人眼在暗適應狀態下，約 1 勒克司即足以辨識階梯邊緣的明暗對比。若把標準訂得過高，會迫使樓梯間裝設大量燈具，反而增加停電時蓄電池負荷、縮短可持續點燈時間；訂得過低則踏面輪廓消失，樓梯間在濃煙下成為最容易發生跌倒與推擠的位置。1985 年以後國內外多起集合住宅與旅館火災的傷亡分析都指出，樓梯間跌倒是延誤避難的重要因素，這是本項數值的立法背景。\n數值對照便於記憶：出口標示燈與避難方向指示燈之表示面平均亮度、緊急電源容量(有效動作時間 20 分鐘以上，一定規模場所為 60 分鐘以上)、樓梯級面照度 1 勒克司，是同一組考點的三支腳。易混淆之處在於「亮度」與「照度」:表示面亮度講的是燈具本身發光面的明暗，單位為燭光每平方公尺；樓梯級面照度講的是被照面接收到的光，單位為勒克司，題目問「級面」「表面」時必屬照度。\n相關考點連結：同一條文脈絡下常一併考避難方向指示燈之設置間隔、走廊轉角處必設、以及地面型指示燈的採用時機；檢修方面則以照度計於樓梯級面實測作為性能判定方式。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-026","樓梯或斜坡通道以外之場所，廣播區域之殘響時間在 3 秒以上時，揚聲器之裝設需符合 r = 3 \u002F 4 QSα\u002Fπ (1 −α) 之計算公式，S 的定義為何？",26,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-028","大型建築物警報設備使用許多中繼器來連結探測器與受信總機，但下列何者不是警報設備中繼器主要功能？",28,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-alarm-evacuation-025","依緊急照明燈認可基準規定，內置電池型緊急電源供電照明時間應維持 1.5 小時以上（供緊急照明燈總數）後，其蓄電池電壓不得小於蓄電池額定電壓多少百分比？",25,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-alarm-evacuation-029","瓦斯濃度達到警報濃度值後，其濃度仍繼續存在，即發出警報，但瓦斯洩漏濃度越高，則警報延遲動作時間越短，此種檢知瓦斯之警報發出方式稱作何種型式？",29,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-alarm-evacuation-024","依各類場所消防安全設備設置標準規定，特別安全梯或緊急昇降機間排煙室之排煙設備設置排煙、進風風管時，下列何者有誤？",24,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-alarm-evacuation-030","在某飯店檢查瓦斯漏氣火警自動警報設備時，何項試驗必須切換成緊急電源之狀態？",30,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-027",113,"有關出口標示燈、避難方向指示燈與緊急照明燈之緊急電源規定，下列敘述何者正確？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-027",112,"依各類場所消防安全設備設置標準之規定，有關緊急電源插座之設置場所與位置規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-027",111,"以絕緣電阻計量測 220 V 電源之火警受信總機回路絕緣電阻，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-027",110,"依緊急廣播設備之揚聲器設置規定，廣播區域超過 100 平方公尺時，距揚聲器 1 公尺處所測得之音壓應為多少分貝以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-027",109,"有關緩降機支固器具之裝置，下列何者與各類場所消防安全設備設置標準之規定不同？",1785129965510]