[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-017":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-017","fire-106-1-alarm-evacuation-017",106,1,17,"檢查緩降機性能時，有關常溫下降試驗之判定中，緩降機最大下降速度應在多少以內？",{"A":16,"B":17,"C":18,"D":19},"100 公分\u002F秒","150 公分\u002F秒","175 公分\u002F秒","200 公分\u002F秒","B",null,[],false,"本題考點：緩降機在《各類場所消防安全設備檢修及申報作業基準》性能檢查中，常溫下降試驗之下降速度合格判定值。\n【正解理由】依《各類場所消防安全設備檢修及申報作業基準》避難器具章之緩降機性能檢查，常溫下降試驗係以最大使用載重進行下降，判定基準為下降速度應在每秒十六公分以上、一百五十公分以下；下限十六公分是避免速度過慢導致避難時間拉長，上限一百五十公分則是確保使用者著地時衝擊在人體可承受範圍內。題目問的是「最大下降速度應在多少以內」，即取上限值一百五十公分／秒，故選 B。\n【逐項排除】\n(A) 100 公分\u002F秒：此值落在合格區間之內，但並非判定基準所定的上限；以它作為判定標準會把速度介於一百至一百五十公分／秒之合格器具誤判為不合格，屬過度嚴格的自訂值。\n(B) 150 公分\u002F秒：與常溫下降試驗之速度上限完全相符，為正解。\n(C) 175 公分\u002F秒：基準並無此判定值；此數值常被誤認為調速器容許誤差後的放寬值，但檢修基準對下降速度並未給予額外寬容範圍。\n(D) 200 公分\u002F秒：明顯超過上限，若真以每秒兩公尺著地，衝擊相當於自約二十公分高度躍下再加上失衡風險，已具傷害之虞，不可能作為合格標準。\n【記憶點】緩降機速度區間記「十六到一百五」——太慢逃不掉、太快摔得慘，常溫下降試驗上限一百五十公分／秒。","緩降機屬於《各類場所消防安全設備設置標準》第 157 條所列的避難器具之一，構造上由調速器、調速器連結部、繩索、緊結金屬配件與著用具組成，靠繩索通過調速器時的摩擦或離心制動把位能轉成熱能，使人員以近乎等速下降。速度區間十六至一百五十公分／秒的由來即在此：人體自由落體加速度為 9.8 m\u002Fs²，若無調速，兩層樓高度落地速度已逾每秒六公尺；把終端速度壓在一點五公尺／秒以內，相當於自約十一公分高度自然跳下的著地衝擊，一般成人可安全承受。下限十六公分／秒則反映避難效率考量——十層樓約三十公尺，以下限速度計算仍需近三分鐘，過慢的器具在實際火場等於失去意義。\n檢修基準對緩降機分外觀檢查、性能檢查兩層。外觀檢查看支固器具有無變形腐蝕、繩索有無斷股、著用具縫合處有無破損、設置空間有無被占用；性能檢查則是常溫下降試驗與（必要時）最大使用載重、最大使用者數之確認，並須確認調速器無異音、繩索無扭結。此處要與「認可基準」區分：認可基準規範的是產品出廠性能，檢修基準規範的是在場設備定期查驗，兩者數值多半一致，但適用時機不同，題目若寫「依認可基準」或「依檢修基準」都指向同一組速度值。\n易混淆數值可整理成表：緩降機下降速度十六至一百五十公分／秒；避難器具支固器具之最大使用載重不得小於一點三倍法定荷重；緩降機設置開口部須有高八十公分以上、寬五十公分以上，或高一百公分以上、寬四十五公分以上；操作面積為零點五平方公尺以上（不含避難器具所占面積），且邊長六十公分以上。\n相關考點連結上，同章節還會考避難器具的減設與免設（架空走廊、直通樓梯、主要構造為防火構造等要件）、以及各類避難器具適用樓層對照——緩降機適用二樓以上十樓以下，救助袋、避難橋、滑臺之適用範圍不同，常與本題併為綜合題型出現。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-016","瓦斯漏氣火警自動警報設備裝置於瓦斯對空氣之比重未滿一之建築物室內時，檢知器設置位置應距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離多少以內？",16,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-018","依各類場所消防安全設備檢修及申報作業基準規定，火焰探測器以動作試驗器確認探測器之動作應在多少時間內方為合格？",18,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-alarm-evacuation-015","依緩降機認可基準規定，緩降機之最大使用載重，應在最大使用人數乘以 W 所得數值以上。下述 W 值何者正確？",15,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-alarm-evacuation-019","一居室設置於地上層，該樓層亦非為無開口樓層，自內部任一點易於識別主要出入口，主要出入口之步行距離在多少以下者，得免設避難方向指示燈？",19,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-alarm-evacuation-014","依各類場所消防安全設備檢修及申報作業基準規定，火警自動警報設備之受信總機前應確保多少公尺以上空間以進行檢查及操作使用？",14,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-alarm-evacuation-020","差動式探測器之動作原理為感應火場中何種參數？",20,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-017",113,"電子工業廠房潔淨區，因潔淨環境及構造特殊，特訂定潔淨區消防安全設備設置要點，對於潔淨室設置吸氣式偵煙探測系統時，依據此設置要點，下列說明何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-017",112,"有一地下建築物總樓地板面積超過 1 千平方公尺，依據各類場所消防安全設備設置標準，下列何者非依法應設之消防安全設備？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-017",111,"下列何者非各類場所消防安全設備設置標準明定應設置防災監控系統綜合操作裝置之場所？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-017",110,"下列那二種避難器具在性能檢查時，均須對其下降空地附近之支持或固定裝置進行判定？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-017",109,"一一九火災通報裝置之設置規定，下列敘述何者錯誤？",1785129965431]