[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-010":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-010","fire-106-1-alarm-evacuation-010",106,1,10,"緩降機設置周圍為避免有操作障礙，因此限制必要操作面積為 M 平方公尺以上（不含避難器具所占面積），但邊長應為 N 公分以上。下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"M：0.5，N：60","M：0.75，N：50","M：1，N：50","M：1.5，N：60","A",null,[],false,"本題考點：避難器具設置時所需之操作面積，考的是《各類場所消防安全設備設置標準》第 167 條附表中緩降機的操作面積與邊長數值。\n【正解理由】依《各類場所消防安全設備設置標準》第 167 條所定，緩降機之操作面積為零點五平方公尺以上（不含避難器具所占面積），但邊長應在六十公分以上；M 為零點五、N 為六十，故選 A。\n【逐項排除】\n(A) M：0.5，N：60：與條文所定緩降機操作面積零點五平方公尺以上、邊長六十公分以上完全相符，為正解。\n(B) M：0.75，N：50：零點七五平方公尺並非本標準採用之操作面積數值，邊長五十公分亦低於法定六十公分。\n(C) M：1，N：50：一平方公尺屬避難梯、避難橋等其他器具的操作面積範疇，與緩降機不同，且邊長數值亦不符。\n(D) M：1.5，N：60：一點五平方公尺為救助袋之操作面積，邊長要求為一公尺以上，被移植到緩降機即為錯誤組合。\n【記憶點】緩降機操作面積「半平方公尺、邊長六十公分」，救助袋才是一點五平方公尺。","避難器具的設置規定由三個層次組成：第 159 條附表決定「哪種場所、哪個樓層可以用哪種器具」，第 160 條至第 166 條規定各器具的構造與固定要求，第 167 條附表則統一規定「操作面積、開口部、下降空間、下降空地」四項空間條件。本題屬第三層，也是計分密度最高的一層。\n\n操作面積的立法目的，是確保避難者在緊急狀況下有足夠空間展開器具、跨越開口部並完成下降動作。緩降機屬單人循環使用的器具，操作者只需在開口部前完成掛勾、放繩、著裝三個動作，所需面積小，故訂為零點五平方公尺以上；但若面積雖足、形狀卻極為狹長，仍會妨礙動作，因此另加「邊長六十公分以上」的形狀限制，這正是本題設計 M 與 N 兩個變數的用意。相對地，救助袋需展開袋體並由多人協助，操作面積為一點五平方公尺以上且邊長一公尺以上；避難梯、避難橋、滑臺等則另有各自數值。\n\n數值對照可整理成一句口訣：緩降機「半平方、六十邊」，救助袋「一點五平方、一公尺邊」。開口部方面，緩降機為高八十公分以上、寬五十公分以上，或高一百公分以上、寬四十五公分以上；下降空間為器具中心半徑零點五公尺圓柱形範圍；下降空地則與下降空間相同範圍。四項條件一起記，可同時應付本條所有變化題。\n\n易混淆概念是「操作面積」與「下降空地」：前者在設置樓層的室內、供操作者使用；後者在地面、供著地時使用，兩者位置與功能完全不同，選項常故意把兩組數值互換。另一個常考點是緩降機的固定部與支固定架，依第 160 條應裝置於使用場所之柱、地板、樑或其他構造上堅固或經補強之部分，並能承受規定荷重。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-009","差動式分布型探測器為熱電偶式時，熱電偶應裝置在裝置面下方多少公分範圍內？",9,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-011","Ｐ型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，不得超過 X 個。受信總機之探測器回路電阻，應在 Y 以下。下列何者正確？",11,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-alarm-evacuation-008","天花板設排氣口或回風口時，偵煙式探測器應裝置於排氣口或回風口周圍多少距離範圍內？",8,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-alarm-evacuation-012","依據緊急照明燈認可基準進行充電試驗時，蓄電池電壓降達額定電壓多少以內時，需能自動充電？",12,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-alarm-evacuation-007","如設置救助袋做為避難器具，下列敘述何者錯誤？",7,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-alarm-evacuation-013","集合住宅計算收容人數以設置避難器具時，每戶收容人數以多少人計算？",13,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-010",113,"下列場所設置的出口標示燈及非設於樓梯或坡道之避難方向指示燈，何者符合規定之要求？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-010",112,"依據緊急照明設備檢修基準性能檢查之判定方法，有關檢查緊急電源容量能否持續 30 分鐘之檢查數量，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-010",111,"依各類場所消防安全設備設置標準規定，有關揚聲器在居室樓地板面積在 X 平方公尺以下，其它非居室部分樓地板面積在 Y 平方公尺以下，且該區域與相鄰接區域揚聲器之水平距離相距 Z 公尺以下時，得免設。則 X、Y、Z 值，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-010",110,"各型探測器在性能試驗中，下列有關其動作試驗的動作時間，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-010",109,"緩降機之設置應保有必要操作面積（不含避難器具所占面積），其相關規定下列何者正確？",1785129965372]