[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-106-1-alarm-evacuation-007":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-106-1-警報與避難系統消防安全設備概要-007","fire-106-1-alarm-evacuation-007",106,1,7,"如設置救助袋做為避難器具，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"位於建築物第七樓層之養老院可採用救助袋作為避難器具","救助袋之長度應無避難上之障礙，且保持一定之安全下滑速度","斜降式救助袋最下端起 1.5 公尺及中心線左右 0.5 公尺以上所圍區域作為下降空間下方必要下降空地","裝置在使用場所之柱、地板、樑或其他構造上堅固或加強部分","C",null,[],false,"本題考點：救助袋作為避難器具之設置規定，重點在斜降式救助袋「下降空間與下降空地」的尺寸數值，屬《各類場所消防安全設備設置標準》第 165 條、第 167 條的範圍。\n【正解理由】依《各類場所消防安全設備設置標準》第 167 條附表所定，斜降式救助袋之下降空地，係自最下端起二點五公尺及中心線左右各一公尺以上所圍範圍；選項所寫「一點五公尺及左右零點五公尺」與法定數值不符，題目問的是錯誤敘述，故選 C。\n【逐項排除】\n(A) 正確。依同標準第 159 條附表，養老院等第一類場所於三樓以上、十樓以下之樓層得設救助袋，第七樓層之養老院採用救助袋合於規定。\n(B) 正確。救助袋之長度應無避難上之障礙並保持適當下滑速度，此為第 165 條對救助袋構造與安全性的要求。\n(C) 錯誤。法定下降空地為最下端起二點五公尺、中心線左右各一公尺以上，本選項把兩個數值都寫小了，是本題的錯誤敘述。\n(D) 正確。避難器具應裝置於使用場所之柱、地板、樑或其他構造上堅固或經補強之部分，係第 158 條至第 160 條對固定部之共通要求。\n【記憶點】斜降式救助袋下降空地記「二點五公尺長、左右各一公尺」，看到 1.5 與 0.5 就是被改過的數字。","救助袋分為斜降式與直降式兩類，設計思維完全不同。斜降式以傾斜袋體讓避難者以可控速度滑降，袋體末端必須拉到地面並固定於固定環，因此地面端需要一塊淨空的「下降空地」；直降式則靠袋體內部摩擦力減速，避難者近乎垂直下滑，所需地面淨空較小。這也是為什麼法規對兩者的下降空間、下降空地分別訂定數值，考題最愛把兩套數值互換。\n\n《各類場所消防安全設備設置標準》第 167 條以附表方式，逐一列出各式避難器具的操作面積、開口部大小、下降空間與下降空地。斜降式救助袋的下降空間為救助袋中心線左右各一公尺、上方一公尺；下降空地則自最下端起二點五公尺、中心線左右各一公尺以上。直降式救助袋的下降空間為救助袋周圍零點五公尺以上，下降空地則與下降空間相同範圍。把「2.5／1」與「0.5」兩組數字分開記，就不會被選項調包。\n\n避難器具的適用樓層與場所類別，規定於第 159 條附表。第一類場所（含養老院、醫院等避難弱者收容場所）因使用者行動能力受限，適用器具以救助袋、避難橋、滑臺等不需自身操作技巧者為主，緩降機、避難梯則多限於二樓、三樓等低樓層。第七樓層的養老院可用救助袋，正是這個立法邏輯的展現。\n\n此條文的其他常見考法：問「開口部之大小」（斜降式救助袋為高六十公分以上、寬六十公分以上）、問「操作面積」（救助袋為一點五平方公尺以上，但邊長須一公尺以上）。建議把第 167 條附表整理成一張表，橫軸為器具種類、縱軸為操作面積／開口部／下降空間／下降空地，一次記完四欄，比逐題背誦省力。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-106-1-alarm-evacuation-006","樓梯、斜坡通道、昇降機之昇降路及管道間等場所，其頂層相差在二層以下、水平距離多少範圍內，視為一火警分區？",6,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-106-1-alarm-evacuation-008","天花板設排氣口或回風口時，偵煙式探測器應裝置於排氣口或回風口周圍多少距離範圍內？",8,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-106-1-alarm-evacuation-005","依各類場所消防安全設備設置標準規定，下列何種場所如設置高感度密閉式撒水頭自動撒水設備，得免設火警自動警報設備？",5,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-106-1-alarm-evacuation-009","差動式分布型探測器為熱電偶式時，熱電偶應裝置在裝置面下方多少公分範圍內？",9,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-106-1-alarm-evacuation-004","依各類場所消防安全設備檢修及申報作業基準規定，1 種光電式局限型偵煙探測器於使用加煙試驗器確認動作之時間，加煙後至動作應在多少時間內方為合格？",4,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-106-1-alarm-evacuation-010","緩降機設置周圍為避免有操作障礙，因此限制必要操作面積為 M 平方公尺以上（不含避難器具所占面積），但邊長應為 N 公分以上。下列何者正確？",10,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-007",113,"醫療機構中的 3 樓，經容納病床數量、從業員工與相關區域之樓地板面積等相關條件評估後，其收容人數為 550 人，該樓層在無減設、免設考量下，至少應設多少具避難器具？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-alarm-evacuation-007",112,"有關揚聲器設置場所之外觀試驗判定要領，依據緊急廣播設備測試報告書，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-alarm-evacuation-007",111,"依消防安全設備及必要檢修項目檢修基準，差動式分布型空氣管式之火災動作或動作持續試驗，不動作或測定之時間超過範圍時，應即確認空氣管與旋塞台之連接部位是否栓緊，且應進行何種試驗？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-alarm-evacuation-007",110,"下列何種火警探測器在認可作業中須進行粉塵試驗？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-alarm-evacuation-007",109,"除火焰式探測器外，一般局限型探測器裝設時，依各類場所消防安全設備設置標準之規定，不得傾斜幾度以上？",1785129965350]