[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-water-chemical-111-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"水與化學系統消防安全設備概要","water-chemical",111,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"近日物流倉庫發生火災頻傳，造成嚴重的環境污染及財產損失，試說明「高架儲存倉庫」之定義及設置自動撒水設備時，其撒水頭配置及進行外觀檢查時，撒水頭之檢查及判定方法。（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"依據消防安全設備及必要檢修項目檢修基準規定，請詳述進行簡易自動滅火設備之性能檢查時，滅火藥劑儲存容器之滅火藥劑量的檢查方法、判定方法及注意事項為何？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"水與化學系統","水與化學系統 · Water & Chemical","室內外消防栓、自動撒水、水霧泡沫,加上二氧化碳、乾粉與惰性氣體滅火設備——法定數值與檢修判定的重災區。","水系統抓消防栓放水壓力與放水量(室內 1.7、室外 2.5 kgf\u002Fcm² 等門檻)、撒水頭配置與撒水頭迴水板高度、水源容量計算;化學系統抓二氧化碳\u002F乾粉\u002F惰性氣體的設計濃度、藥劑量計算與放射時間,並注意《檢修基準》的性能檢查與判定值。計算題全 corpus 61 題,次於火災學。",[23,28,32,36,41,46,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-111-1-water-chemical-001","依各類場所消防安全設備設置標準規定，下列何種場所不需設置室外消防栓設備？","C",true,{"webId":29,"number":15,"stem":30,"answer":31,"indexable":27},"fire-111-1-water-chemical-002","有關室外消防栓與室內消防栓之瞄子放水壓力之敘述，下列何者正確？","B",{"webId":33,"number":34,"stem":35,"answer":26,"indexable":27},"fire-111-1-water-chemical-003",3,"某公共危險物品場所設置室外消防栓設備，在裝置全部消防栓數量 5 支時，其所需之水源容量至少應為多少立方公尺以上？",{"webId":37,"number":38,"stem":39,"answer":40,"indexable":27},"fire-111-1-water-chemical-004",4,"裝置於舞臺之開放式自動撒水設備，依規定下列何者正確？","D",{"webId":42,"number":43,"stem":44,"answer":45,"indexable":27},"fire-111-1-water-chemical-005",5,"有關移動式泡沫滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？","A",{"webId":47,"number":48,"stem":49,"answer":31,"indexable":27},"fire-111-1-water-chemical-006",6,"消防幫浦之防止水溫上升用排放裝置，防止水溫上升用之排水管內之流水量，當幫浦在全閉狀態下連續運轉時，不使幫浦內部水溫，…",{"webId":51,"number":52,"stem":53,"answer":45,"indexable":27},"fire-111-1-water-chemical-007",7,"下列有關撒水頭設置之敘述，何者正確？",{"webId":55,"number":56,"stem":57,"answer":31,"indexable":27},"fire-111-1-water-chemical-008",8,"固定式泡沫滅火設備（低發泡）進行綜合檢查作業時，發泡倍率應在幾倍以上？",{"webId":59,"number":60,"stem":61,"answer":45,"indexable":27},"fire-111-1-water-chemical-009",9,"泡沫滅火設備之減水警報裝置進行性能檢查時，當呼水槽水量減少到多少時，應發出警報？",{"webId":63,"number":64,"stem":65,"answer":26,"indexable":27},"fire-111-1-water-chemical-010",10,"樓地板面積 250 平方公尺之變壓器室，依各類場所消防安全設備設置標準規定，可選擇下列何種消防安全設備？①水霧 ②泡…",{"webId":67,"number":68,"stem":69,"answer":31,"indexable":27},"fire-111-1-water-chemical-011",11,"依各類場所消防安全設備設置標準規定，消防專用蓄水池應設置於消防車能接近至多少公尺範圍內，易於抽取處？",{"webId":71,"number":72,"stem":73,"answer":26,"indexable":27},"fire-111-1-water-chemical-012",12,"有關水霧滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",{"webId":75,"number":76,"stem":77,"answer":31,"indexable":27},"fire-111-1-water-chemical-013",13,"有關自動撒水設備末端查驗閥之敘述，下列何者正確？",{"webId":79,"number":80,"stem":81,"answer":45,"indexable":27},"fire-111-1-water-chemical-014",14,"開放式自動撒水設備之自動啟動裝置，感知撒水頭應設在裝置面距樓地板面高度多少公尺以下，且能有效探測火災處？",{"webId":83,"number":84,"stem":85,"answer":45,"indexable":27},"fire-111-1-water-chemical-015",15,"採用移動式放射方式之乾粉滅火設備，藥劑種類為第四種乾粉時，每一具噴射瞄子所需藥劑放射量為何？",{"webId":87,"number":88,"stem":89,"answer":26,"indexable":27},"fire-111-1-water-chemical-016",16,"乾粉滅火設備進行性能檢查時，關於滅火藥劑量之敘述，下列何者正確？",{"webId":91,"number":92,"stem":93,"answer":31,"indexable":27},"fire-111-1-water-chemical-017",17,"惰性氣體滅火設備進行綜合檢查時，採低壓式者進行放射試驗時，其放射試驗所需之藥劑量，為該放射區域所設滅火藥劑量之多少以…",{"webId":95,"number":96,"stem":97,"answer":26,"indexable":27},"fire-111-1-water-chemical-018",18,"依各類場所消防安全設備設置標準規定，總樓地板面積 100 平方公尺之何種場所應設置滅火器？ ①咖啡廳 ②幼兒園 ③陳…",{"webId":99,"number":100,"stem":101,"answer":31,"indexable":27},"fire-111-1-water-chemical-019",19,"下列有關滅火器性能檢查之敘述，何者正確？",{"webId":103,"number":104,"stem":105,"answer":45,"indexable":27},"fire-111-1-water-chemical-020",20,"電子工業廠房潔淨室設置消防安全設備，下列敘述何者正確？",{"webId":107,"number":108,"stem":109,"answer":45,"indexable":27},"fire-111-1-water-chemical-021",21,"下列有關乾粉滅火設備設置之規定，何者正確？",{"webId":111,"number":112,"stem":113,"answer":26,"indexable":27},"fire-111-1-water-chemical-022",22,"有關水道連結型自動撒水設備進行綜合檢查時，其放水壓力應為多少？",{"webId":115,"number":116,"stem":117,"answer":45,"indexable":27},"fire-111-1-water-chemical-023",23,"簡易自動滅火設備進行性能檢查時，蓄壓式滅火藥劑儲存容器滅火藥劑量應與標示差異不超過多少？",{"webId":119,"number":120,"stem":121,"answer":40,"indexable":27},"fire-111-1-water-chemical-024",24,"十樓以下建築物之樓層供百貨商場使用，如達到設置自動撒水設備條件，使用密閉式一般反應型撒水頭時，其水源容量應符合幾個撒…",{"webId":123,"number":12,"stem":124,"answer":26,"indexable":27},"fire-111-1-water-chemical-025","泡沫試料淨重為 200 g，還原數值如下，則 25%還原時間為何？時間（分） 0 0.5 1 1.5 2 2.5 3…",{"webId":126,"number":127,"stem":128,"answer":26,"indexable":27},"fire-111-1-water-chemical-026",26,"壓力開關高程 0 m，屋頂水箱高程 33 m，最高處撒水頭高程 30 m，加壓送水裝置利用啟動用壓力開關連動啟動。當…",{"webId":130,"number":131,"stem":132,"answer":40,"indexable":27},"fire-111-1-water-chemical-027",27,"自動撒水採用密閉乾式或預動式自動撒水設備，撒水頭動作後，流水檢知裝置應在幾分鐘內，使撒水頭放水？",{"webId":134,"number":135,"stem":136,"answer":40,"indexable":27},"fire-111-1-water-chemical-028",28,"依各類場所消防安全設備設置標準之規定，下列何者應設自動撒水設備？",{"webId":138,"number":139,"stem":140,"answer":40,"indexable":27},"fire-111-1-water-chemical-029",29,"變電站場所設置水霧滅火設備，放射區域 6 個分區，其消防幫浦出水量需達每分鐘 X 公升以上；且每顆水霧噴頭放水壓力均…",{"webId":142,"number":143,"stem":144,"answer":26,"indexable":27},"fire-111-1-water-chemical-030",30,"有關消防安全設備檢修完成標示附加位置，下列敘述何者錯誤？",{"webId":146,"number":147,"stem":148,"answer":31,"indexable":27},"fire-111-1-water-chemical-031",31,"應設置消防專用蓄水池之場所規定，下列何者正確？",{"webId":150,"number":151,"stem":152,"answer":26,"indexable":27},"fire-111-1-water-chemical-032",32,"二氧化碳滅火設備屬於公共危險物品等場所的那一類滅火設備？",{"webId":154,"number":155,"stem":156,"answer":40,"indexable":27},"fire-111-1-water-chemical-033",33,"二氧化碳滅火設備配管，下列設置規定何者錯誤？",{"webId":158,"number":159,"stem":160,"answer":45,"indexable":27},"fire-111-1-water-chemical-034",34,"第五種滅火設備除滅火器外之其他設備，有關滅火效能值核算之規定，下列何者錯誤？",{"webId":162,"number":163,"stem":164,"answer":26,"indexable":27},"fire-111-1-water-chemical-035",35,"二氧化碳滅火設備採全區放射，其噴頭設置規定下列何者錯誤？",{"webId":166,"number":167,"stem":168,"answer":45,"indexable":27},"fire-111-1-water-chemical-036",36,"二氧化碳滅火設備，採用低壓式滅火藥劑儲存容器時，壓力在何範圍會發出警報？",{"webId":170,"number":171,"stem":172,"answer":31,"indexable":27},"fire-111-1-water-chemical-037",37,"依規定 112 年度滅火器檢查合格時，應採用那種顏色檢修環？",{"webId":174,"number":175,"stem":176,"answer":26,"indexable":27},"fire-111-1-water-chemical-038",38,"一間變壓機房採全區放射二氧化碳滅火設備，其防護區域體積 1250 立方公尺，無其它開口部，此防護區域需要多少二氧化碳…",{"webId":178,"number":179,"stem":180,"answer":45,"indexable":27},"fire-111-1-water-chemical-039",39,"可燃性高壓氣體儲存場所任一點至滅火器之步行距離在 X 公尺以下，並不得妨礙出入作業；每具滅火器對普通火災具有 Y 個…",{"webId":182,"number":183,"stem":184,"answer":31,"indexable":27},"fire-111-1-water-chemical-040",40,"二氧化碳滅火設備採全區放射方式，採用高壓系統在進行綜合檢查時，以空氣或氮氣進行放射試驗，所需空氣量或氮氣量，應就放射…",50,1785129971008]