[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-water-chemical-108-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"水與化學系統消防安全設備概要","water-chemical",108,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"泡沫滅火設備進行綜合檢查時，固定式泡沫滅火設備如採用低發泡水成膜泡沫滅火藥劑，請說明泡沫試料採集方法、發泡倍率及 25%還原時間之測定方式及合格標準。（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"請說明水道連結型自動撒水設備之適用場所。（10 分）並請比較密閉濕式撒水系統（一般反應型撒水頭）及水道連結型自動撒水設備在放水壓力、每分鐘放水量、水源容量等之異同。（15 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"水與化學系統","水與化學系統 · Water & Chemical","室內外消防栓、自動撒水、水霧泡沫,加上二氧化碳、乾粉與惰性氣體滅火設備——法定數值與檢修判定的重災區。","水系統抓消防栓放水壓力與放水量(室內 1.7、室外 2.5 kgf\u002Fcm² 等門檻)、撒水頭配置與撒水頭迴水板高度、水源容量計算;化學系統抓二氧化碳\u002F乾粉\u002F惰性氣體的設計濃度、藥劑量計算與放射時間,並注意《檢修基準》的性能檢查與判定值。計算題全 corpus 61 題,次於火災學。",[23,28,31,36,40,45,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-108-1-water-chemical-001","在應設置室內消防栓設備之場所，但設有室外消防栓設備時，在第一層水平距離 X 公尺以下、第二層步行距離 Y 公尺以下有…","D",true,{"webId":29,"number":15,"stem":30,"answer":26,"indexable":27},"fire-108-1-water-chemical-002","自動撒水設備竣工時，應做加壓試驗。但密閉乾式管系應併行空氣壓試驗，試驗時，應使空氣壓力達到 X MPa 之標準，其壓…",{"webId":32,"number":33,"stem":34,"answer":35,"indexable":27},"fire-108-1-water-chemical-003",3,"中央主管機關認定儲存大量可燃物之場所天花板高度超過 X 公尺，或其他場所天花板高度超過 Y 公尺者，應採用放水型撒水…","C",{"webId":37,"number":38,"stem":39,"answer":26,"indexable":27},"fire-108-1-water-chemical-004",4,"密閉乾式或預動式自動撒水設備，下列設置規定何者正確？",{"webId":41,"number":42,"stem":43,"answer":44,"indexable":27},"fire-108-1-water-chemical-005",5,"開放式自動撒水設備之自動及手動啟動裝置，下列設置規定何者正確？","A",{"webId":46,"number":47,"stem":48,"answer":49,"indexable":27},"fire-108-1-water-chemical-006",6,"使用密閉式撒水頭之自動撒水設備末端之查驗閥，下列設置規定何者正確？","B",{"webId":51,"number":52,"stem":53,"answer":26,"indexable":27},"fire-108-1-water-chemical-007",7,"有關水霧滅火設備，下列設置規定何者錯誤？",{"webId":55,"number":56,"stem":57,"answer":35,"indexable":27},"fire-108-1-water-chemical-008",8,"移動式泡沫滅火設備之加壓送水裝置使用消防幫浦時，若同一樓層設 3 個泡沫消防栓箱時，其出水量應在每分鐘多少公升以上？",{"webId":59,"number":60,"stem":61,"answer":49,"indexable":27},"fire-108-1-water-chemical-009",9,"有一總機室，設置二氧化碳滅火設備，採全區放射方式，其每立方公尺防護區域所需滅火藥劑量為多少公斤？",{"webId":63,"number":64,"stem":65,"answer":26,"indexable":27},"fire-108-1-water-chemical-010",10,"有一電信機械室，設置二氧化碳滅火設備，採全區放射方式，其所核算之滅火藥劑量應於多少秒內全部放射完畢？",{"webId":67,"number":68,"stem":69,"answer":35,"indexable":27},"fire-108-1-water-chemical-011",11,"二氧化碳滅火設備使用氣體啟動者，啟動用氣體容器之內容積應有 1 公升以上，其所儲存之二氧化碳重量在 0.6 公斤以上…",{"webId":71,"number":72,"stem":73,"answer":44,"indexable":27},"fire-108-1-water-chemical-012",12,"主成分為碳酸氫鉀及尿素化合物之乾粉滅火藥劑，採全區放射方式時，每立方公尺防護區域所需滅火藥劑量為多少公斤？",{"webId":75,"number":76,"stem":77,"answer":49,"indexable":27},"fire-108-1-water-chemical-013",13,"依各類場所消防安全設備設置標準之規定，乾粉滅火設備配管及閥類，下列設置規定何者錯誤？",{"webId":79,"number":80,"stem":81,"answer":35,"indexable":27},"fire-108-1-water-chemical-014",14,"依各類場所消防安全設備設置標準之規定，加壓式乾粉滅火設備應設壓力調整裝置，可調整壓力至若干 MPa 以下？",{"webId":83,"number":84,"stem":85,"answer":35,"indexable":27},"fire-108-1-water-chemical-015",15,"依各類場所消防安全設備檢修及申報作業基準，對蓄壓式二氧化碳滅火器及海龍滅火器進行重量檢查時，如失重超過多少%以上或壓…",{"webId":87,"number":88,"stem":89,"answer":26,"indexable":27},"fire-108-1-water-chemical-016",16,"依各類場所消防安全設備檢修及申報作業基準，公共危險物品等場所達顯著滅火困難者設置之第一種滅火設備之室內消防栓，其放水…",{"webId":91,"number":92,"stem":93,"answer":35,"indexable":27},"fire-108-1-water-chemical-017",17,"依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備之第一種消防栓水帶及瞄子檢查方法，製造年份超過 10 年…",{"webId":95,"number":96,"stem":97,"answer":26,"indexable":27},"fire-108-1-water-chemical-018",18,"依各類場所消防安全設備檢修及申報作業基準，固定式泡沫滅火設備（低發泡）綜合檢查，設置泡沫頭者，每次選擇全部放射區域數…",{"webId":99,"number":100,"stem":101,"answer":35,"indexable":27},"fire-108-1-water-chemical-019",19,"依各類場所消防安全設備檢修及申報作業基準，有關高壓式二氧化碳滅火藥劑儲存容器之滅火藥劑量檢查方法之注意事項中，鈷 6…",{"webId":103,"number":104,"stem":105,"answer":44,"indexable":27},"fire-108-1-water-chemical-020",20,"公共危險物品等場所之滅火設備分類，下列敘述何者錯誤？",{"webId":107,"number":108,"stem":109,"answer":49,"indexable":27},"fire-108-1-water-chemical-021",21,"某鍋爐房樓地板面積為 20 m×15 m，依法其所需之滅火效能值為何？",{"webId":111,"number":112,"stem":113,"answer":44,"indexable":27},"fire-108-1-water-chemical-022",22,"有關潔淨藥劑氣體滅火設備滅火藥劑主要成分之敘述，下列何者正確？",{"webId":115,"number":116,"stem":117,"answer":49,"indexable":27},"fire-108-1-water-chemical-023",23,"依各類場所消防安全設備設置標準之規定，有關應設置室外消防栓設備之場所，下列敘述何者正確？",{"webId":119,"number":120,"stem":121,"answer":35,"indexable":27},"fire-108-1-water-chemical-024",24,"某一 15 樓層之建築物，其消防安全設備同時設有第一種室內消防栓及自動撒水設備，其屋頂水箱容量至少應為下列何者？",{"webId":123,"number":12,"stem":124,"answer":26,"indexable":27},"fire-108-1-water-chemical-025","下列何者不屬於各類場所消防安全設備設置標準第 8 條所規定的滅火設備？",{"webId":126,"number":127,"stem":128,"answer":49,"indexable":27},"fire-108-1-water-chemical-026",26,"依各類場所消防安全設備設置標準之規定，建築物高度超過 60 公尺者，連結送水管應採用濕式，其中繼幫浦設置規定之敘述何…",{"webId":130,"number":131,"stem":132,"answer":35,"indexable":27},"fire-108-1-water-chemical-027",27,"依各類場所消防安全設備設置標準之規定，室外消防栓於其 I 公尺範圍內附設水帶箱，在 J 公尺以內，保持空曠，不得堆放…",{"webId":134,"number":135,"stem":136,"answer":44,"indexable":27},"fire-108-1-water-chemical-028",28,"依法令規定在應設水霧、泡沫、乾粉、二氧化碳滅火設備之場所，但外牆開口面積（常時開放部分）達該層樓地板面積百分之多少以…",{"webId":138,"number":139,"stem":140,"answer":49,"indexable":27},"fire-108-1-water-chemical-029",29,"有一室內停車空間，其防護區為 25 m × 16 m × 4 m，未設自動關閉裝置之開口部面積為 10 m2，擬設置…",{"webId":142,"number":143,"stem":144,"answer":44,"indexable":27},"fire-108-1-water-chemical-030",30,"依滅火器設置規定，下列何者錯誤？",{"webId":146,"number":147,"stem":148,"answer":26,"indexable":27},"fire-108-1-water-chemical-031",31,"第四種乾粉滅火藥劑儲存容器，有關充填比之規定，下列何者正確？",{"webId":150,"number":151,"stem":152,"answer":44,"indexable":27},"fire-108-1-water-chemical-032",32,"依法令規定下列場所何者應設置滅火器？",{"webId":154,"number":155,"stem":156,"answer":49,"indexable":27},"fire-108-1-water-chemical-033",33,"某百貨商場（10 樓以下）內設有一般反應型撒水頭 15 個，試問其消防幫浦最低出水量應為何？",{"webId":158,"number":159,"stem":160,"answer":26,"indexable":27},"fire-108-1-water-chemical-034",34,"依各類場所消防安全設備設置標準之規定，水霧滅火設備之加壓送水裝置使用消防幫浦時，用於防護電氣設備者，每一個水霧噴頭壓…",{"webId":162,"number":163,"stem":164,"answer":35,"indexable":27},"fire-108-1-water-chemical-035",35,"依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備呼水裝置之減水警報裝置，當水量減少至多少前應發出警報？",{"webId":166,"number":167,"stem":168,"answer":35,"indexable":27},"fire-108-1-water-chemical-036",36,"依各類場所消防安全設備設置標準之規定，高發泡放出口在全區放射防護區域內，樓地板面積每多少平方公尺應至少設置 1 個，…",{"webId":170,"number":171,"stem":172,"answer":49,"indexable":27},"fire-108-1-water-chemical-037",37,"進行滅火器之檢查時，有關一般注意事項，下列何者錯誤？",{"webId":174,"number":175,"stem":176,"answer":44,"indexable":27},"fire-108-1-water-chemical-038",38,"依各類場所消防安全設備檢修及申報作業基準，有關乾粉滅火藥劑判定方法，乾粉藥劑不得有雜質、變質、固化等情形，且以手輕握…",{"webId":178,"number":179,"stem":180,"answer":44,"indexable":27},"fire-108-1-water-chemical-039",39,"依各類場所消防安全設備設置標準之規定，公共危險物品室外儲槽場所之冷卻撒水設備如以幫浦方式進行加壓時，實際測得之放射量…",{"webId":182,"number":183,"stem":184,"answer":26,"indexable":27},"fire-108-1-water-chemical-040",40,"電動機之使用應符合之相關規定，下列何者錯誤？",50,1785129971033]