[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-fire-law-109-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"消防法規概要","fire-law",109,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，公共危險物品室外儲存場所僅限於儲存那些公共危險物品？另該室外儲存場所設置架臺者，其構造及設備應符合那些規定？（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"依建築技術規則建築設計施工編規定，高層建築物應設置防災中心，請問依該規定防災中心應設置之樓層及其樓地板面積為何？又依各類場所消防安全設備設置標準規定，防災中心之位置及構造，應符合那些規定？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"消防法規","消防法規 · Fire Code","《消防法》《各類場所消防安全設備設置標準》為主戰場:條號、數值、場所分類——四科裡最能靠背熟條文直接拿分的一科。","核心是《各類場所消防安全設備設置標準》的應設場所與數值門檻,加《消防法》及施行細則的權責與罰則、《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》。條文中的數字(面積、樓層、距離、期限)是命題最愛;甲乙丙丁類場所分類幾乎每年出現。",[23,28,32,37,42,46,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-109-1-fire-law-001","依消防法、消防法施行細則之規定，有關一定規模以上供公眾使用建築物，下列敘述何者正確？","C",true,{"webId":29,"number":15,"stem":30,"answer":31,"indexable":27},"fire-109-1-fire-law-002","依消防法之規定，得逕處其管理權人罰鍰之違法行為，下列敘述何者正確？","D",{"webId":33,"number":34,"stem":35,"answer":36,"indexable":27},"fire-109-1-fire-law-003",3,"依消防法、消防法施行細則之規定，有關消防防護計畫應包括事項，下列敘述何者正確？","A",{"webId":38,"number":39,"stem":40,"answer":41,"indexable":27},"fire-109-1-fire-law-004",4,"依消防法施行細則之規定，針對消防安全設備施工中須經試驗或勘驗事項之查核，並製作紀錄是屬於下列那個項目之內容？","B",{"webId":43,"number":44,"stem":45,"answer":31,"indexable":27},"fire-109-1-fire-law-005",5,"依消防設備師及消防設備士管理辦法之規定，直轄市、縣（市）之消防設備師或消防設備士達多少人以上者，得組織直轄市、縣（市…",{"webId":47,"number":48,"stem":49,"answer":41,"indexable":27},"fire-109-1-fire-law-006",6,"依消防設備師及消防設備士管理辦法之規定，如通過消防設備士考試，取得證書日起每 3 年應接受講習 1 次或取得累計積分…",{"webId":51,"number":52,"stem":53,"answer":26,"indexable":27},"fire-109-1-fire-law-007",7,"依消防安全設備檢修專業機構管理辦法之規定，成立消防安全設備檢修專業機構，必須聘僱多少專技人員？",{"webId":55,"number":56,"stem":57,"answer":41,"indexable":27},"fire-109-1-fire-law-008",8,"依消防安全設備檢修專業機構管理辦法之規定，消防安全設備檢修專業機構所屬消防設備師或消防設備士檢修不實經裁罰達 5 件…",{"webId":59,"number":60,"stem":61,"answer":36,"indexable":27},"fire-109-1-fire-law-009",9,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關地下儲槽場所位置、構造及設備之規定，下列敘…",{"webId":63,"number":64,"stem":65,"answer":41,"indexable":27},"fire-109-1-fire-law-010",10,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，室內儲槽場所之儲槽專用室出入口，應設置多…",{"webId":67,"number":68,"stem":69,"answer":41,"indexable":27},"fire-109-1-fire-law-011",11,"依各類場所消防安全設備設置標準之規定，下列那一種火警探測器不適合裝設在麵粉廠灰塵會大量滯留的場所？",{"webId":71,"number":72,"stem":73,"answer":26,"indexable":27},"fire-109-1-fire-law-012",12,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關於供作六類物品製造場所或一般處理場所使用之…",{"webId":75,"number":76,"stem":77,"answer":41,"indexable":27},"fire-109-1-fire-law-013",13,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，儲存倉庫應為一層建築物，其高度不得超過 …",{"webId":79,"number":80,"stem":81,"answer":26,"indexable":27},"fire-109-1-fire-law-014",14,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，關於可燃性高壓氣體儲存場所構造、設備及安全管理…",{"webId":83,"number":84,"stem":85,"answer":36,"indexable":27},"fire-109-1-fire-law-015",15,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關販賣場所之規定，下列敘述何者正確？",{"webId":87,"number":88,"stem":89,"answer":41,"indexable":27},"fire-109-1-fire-law-016",16,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，一般瓦斯行存放多少公斤以上液化石油氣，應…",{"webId":91,"number":92,"stem":93,"answer":36,"indexable":27},"fire-109-1-fire-law-017",17,"依防火牆及防火水幕設置基準之規定，防火水幕之防護高度在 10 公尺以下時，其每公尺水幕長度放水量應在每分鐘多少公升以…",{"webId":95,"number":96,"stem":97,"answer":26,"indexable":27},"fire-109-1-fire-law-018",18,"有一固態酒精儲槽水平剖面半徑為 10 公尺，依防火牆及防火水幕設置基準，其假想火面高度應為多少公尺？",{"webId":99,"number":100,"stem":101,"answer":31,"indexable":27},"fire-109-1-fire-law-019",19,"依可燃性高壓氣體儲存場所防爆牆設置基準之規定，防爆牆長度應超過設置方位儲存場所建築物牆面長度，其牆腳與儲存場所建築物…",{"webId":103,"number":104,"stem":105,"answer":26,"indexable":27},"fire-109-1-fire-law-020",20,"依可燃性高壓氣體儲存場所防護牆設置基準之規定，下列敘述何者正確？",{"webId":107,"number":108,"stem":109,"answer":36,"indexable":27},"fire-109-1-fire-law-021",21,"依各類場所消防安全設備設置標準，有關使用密閉式撒水頭自動撒水設備末端查驗閥之規定，下列敘述何者正確？",{"webId":111,"number":112,"stem":113,"answer":41,"indexable":27},"fire-109-1-fire-law-022",22,"依各類場所消防安全設備設置標準之規定，二氧化碳滅火設備採全區放射方式時，啟動裝置開關或拉桿開始動作至儲存容器之容器閥…",{"webId":115,"number":116,"stem":117,"answer":31,"indexable":27},"fire-109-1-fire-law-023",23,"依各類場所消防安全設備設置標準，有關一一九火災通報裝置設置之規定，下列敘述何者正確？",{"webId":119,"number":120,"stem":121,"answer":26,"indexable":27},"fire-109-1-fire-law-024",24,"依各類場所消防安全設備設置標準之規定，有一容納超過 300 人老人福利機構餐廳，其樓地板面積在多少平方公尺以上，廚房…",{"webId":123,"number":12,"stem":124,"answer":26,"indexable":27},"fire-109-1-fire-law-025","依各類場所消防安全設備設置標準之規定，面積 400 坪的知名餐廳，所設置滅火器核算之最低滅火效能值應為多少？",{"webId":126,"number":127,"stem":128,"answer":41,"indexable":27},"fire-109-1-fire-law-026",26,"原有照護思覺失調患者的康復之家想增設自動滅火設備，如採用小區劃型撒水頭（以第一種感度為限），依各類場所消防安全設備設…",{"webId":130,"number":131,"stem":132,"answer":26,"indexable":27},"fire-109-1-fire-law-027",27,"有一 500 平方公尺地下停車場，採水霧滅火設備，依各類場所消防安全設備設置標準，其水源容量應保持多少立方公尺以上？",{"webId":134,"number":135,"stem":136,"answer":36,"indexable":27},"fire-109-1-fire-law-028",28,"依各類場所消防安全設備設置標準，有關裝設瓦斯漏氣火警自動警報設備之規定，下列敘述何者錯誤？",{"webId":138,"number":139,"stem":140,"answer":26,"indexable":27},"fire-109-1-fire-law-029",29,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，有關幫浦性能之規定，全閉揚程應為性能曲線上全揚程之多少以下？",{"webId":142,"number":143,"stem":144,"answer":36,"indexable":27},"fire-109-1-fire-law-030",30,"依各類場所消防安全設備檢修及申報作業基準，有關避難器具外觀檢查之規定，緩降機下降空間之判定，在無其他突出物干擾的情境…",{"webId":146,"number":147,"stem":148,"answer":41,"indexable":27},"fire-109-1-fire-law-031",31,"依各類場所消防安全設備設置標準，有關泡沫原液儲存量、泡沫原液與水混合使用濃度之規定，下列敘述何者正確？",{"webId":150,"number":151,"stem":152,"answer":31,"indexable":27},"fire-109-1-fire-law-032",32,"依各類場所消防安全設備檢修及申報作業基準，有關滅火器外觀檢查之規定，滅火器本體上端與樓地板面之距離，18 公斤以上者…",{"webId":154,"number":155,"stem":156,"answer":26,"indexable":27},"fire-109-1-fire-law-033",33,"依各類場所消防安全設備檢修及申報作業基準之規定，各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理…",{"webId":158,"number":159,"stem":160,"answer":41,"indexable":27},"fire-109-1-fire-law-034",34,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，有關幫浦性能之規定，幫浦所消耗之動力，在額定出水量 150%時，其軸…",{"webId":162,"number":163,"stem":164,"answer":41,"indexable":27},"fire-109-1-fire-law-035",35,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，裝設消防撒水幫浦，設計水量為 600 公升\u002F分，其設計揚程為 …",{"webId":166,"number":167,"stem":168,"answer":41,"indexable":27},"fire-109-1-fire-law-036",36,"依避難器具支固器具及固定部之結構、強度計算及施工方法之規定，裝置避難器具固定部材料，使用直徑 1 公分錨定螺栓，設定…",{"webId":170,"number":171,"stem":172,"answer":36,"indexable":27},"fire-109-1-fire-law-037",37,"依建築技術規則建築設計施工編之定義，每層陽臺面積之和，以不超過建築面積多少為限？其未達 8 平方公尺者，得建築 8 …",{"webId":174,"number":175,"stem":176,"answer":36,"indexable":27},"fire-109-1-fire-law-038",38,"依建築技術規則建築設計施工編之定義，經主管機關認可後，下列何者屬「防火設備」？",{"webId":178,"number":179,"stem":180,"answer":36,"indexable":27},"fire-109-1-fire-law-039",39,"依各類場所消防安全設備設置標準之規定，以防護區域每平方公尺每分鐘放水量來看，儲存可燃物場所設置放水型撒水頭是一般場所…",{"webId":182,"number":183,"stem":184,"answer":41,"indexable":27},"fire-109-1-fire-law-040",40,"依建築技術規則建築設計施工編之規定，閣樓樓地板面積占該建築物建築面積多少以上時，視為另一樓層？",50,1785129968210]