[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-alarm-evacuation-110-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"警報與避難系統消防安全設備概要","alarm-evacuation",110,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"火警自動警報設備是偵測火災發生非常重要的消防安全設備，請依據各類場所消防安全設備設置標準，試述裝置火警受信總機之位置相關規定為何？另有關 P 型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，不得超過幾個？探測器回路電阻，應在多少以下？且所使用之緊急電源，應使用蓄電池設備，其容量能使其有效動作應在多少分鐘以上？（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"請依據各類場所消防安全設備設置標準，試述每一火警分區，火警發信機之設置規定？另設有火警發信機之處所，其標示燈應平時保持明亮，其透明罩為圓弧形，裝置後突出牆面，標示燈與裝置面應成多少度角，在多少公尺距離內須無遮視物且明顯易見？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"警報與避難系統","警報與避難 · Alarm & Egress","探測器、受信總機、緊急廣播,加上標示設備、緊急照明與避難器具——條號最零碎,也最吃「表格記憶」。","警報系統抓火警分區劃定原則、各型探測器(差動式局限型\u002F分布型、定溫式、偵煙式)的裝置場所與高度限制、受信總機與緊急電源;避難系統抓出口\u002F避難方向指示燈的設置與有效範圍、緊急照明照度、緩降機與避難器具的設置數量與開口面規定。條文以表格呈現者多,建議整理成對照表背。",[23,28,32,36,41,45,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-001","下列有關建築物火警分區之劃定，何者符合各類場所消防安全設備設置標準的規定？","D",true,{"webId":29,"number":15,"stem":30,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-002","某樓高 12 層觀光旅館於最高樓層開設之餐廳，依各類場所消防安全設備設置標準之規定，其位於同樓層的廚房無須設置下列何…","A",{"webId":33,"number":34,"stem":35,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-003",3,"建築物有某一樓層樓地板面積 900 平方公尺且設置之避難方向指示燈均為 C 級，該樓層最有可能為下列何種用途？",{"webId":37,"number":38,"stem":39,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-004",4,"有一棟總樓地板面積 4,000 平方公尺的七層辦公建築物，當起火層為地上第二層時，下列有關其火警自動警報設備分區鳴動…","C",{"webId":42,"number":43,"stem":44,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-005",5,"避難方向指示燈之認可作業中，其引導燈具不包括下列何種附加功能？",{"webId":46,"number":47,"stem":48,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-006",6,"緊急廣播設備在樓梯或斜坡通道以外之場所，其設置之揚聲器採性能設計時，在揚聲器標示上如加註下列那二種項目者，該廣播區域…","B",{"webId":51,"number":52,"stem":53,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-007",7,"下列何種火警探測器在認可作業中須進行粉塵試驗？",{"webId":55,"number":56,"stem":57,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-008",8,"下列何組感知線型或分布型探測器在進行外觀試驗時，均須判定其感熱元件之極性有無誤接？",{"webId":59,"number":60,"stem":61,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-009",9,"瓦斯漏氣火警自動警報設備之性能試驗中，下列有關串接配線試驗之測試及判定，何者與消防安全設備測試報告書測試方法及判定要…",{"webId":63,"number":64,"stem":65,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-010",10,"各型探測器在性能試驗中，下列有關其動作試驗的動作時間，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":67,"number":68,"stem":69,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-011",11,"特別安全梯間與緊急昇降機間兼用之排煙室，如設置排煙管道及進風管道，下列何者在綜合試驗中應判定合格？",{"webId":71,"number":72,"stem":73,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-012",12,"建築物某一樓層（A 區）通往直通樓梯（B 區）的出口標示燈（L）附有誘導音裝置，並設置有停止專用偵煙式探測器（D）及…",{"webId":75,"number":76,"stem":77,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-013",13,"容易受風影響之場所（如大廳、禮拜堂、大樓頂上之機械室等），依消防安全設備及必要檢修項目檢修基準之規定，可在下列何種探…",{"webId":79,"number":80,"stem":81,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-014",14,"對火警自動警報設備二信號式受信總機進行火災表示之性能檢查時，接到第 1 報火警信號但尚未接到第 2 報火警信號時，下…",{"webId":83,"number":84,"stem":85,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-015",15,"對空氣管式之差動式分布型探測器進行空氣注入之性能檢查時，下列何種試驗無須量測探測器導通與否？",{"webId":87,"number":88,"stem":89,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-016",16,"建築物之避難器具設置緩降機時，對其開口部進行外觀檢查之判定，下列何者合格？",{"webId":91,"number":92,"stem":93,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-017",17,"下列那二種避難器具在性能檢查時，均須對其下降空地附近之支持或固定裝置進行判定？",{"webId":95,"number":96,"stem":97,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-018",18,"下列避難器具架設完成後，進行綜合檢查時，何者應判定不合格？",{"webId":99,"number":100,"stem":101,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-019",19,"對於設置在地下建築物、地下層及地上層三者之居室的緊急照明燈進行性能檢查，依照消防安全設備及必要檢修項目檢修基準之規定…",{"webId":103,"number":104,"stem":105,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-020",20,"有關辦公大樓排煙設備之啟動裝置在消防安全設備及必要檢修項目檢修基準之性能及綜合檢查的檢查及判定方法，下列敘述何者錯誤…",{"webId":107,"number":108,"stem":109,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-021",21,"下列有關免設火警探測器之場所，何者錯誤？",{"webId":111,"number":112,"stem":113,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-022",22,"有一地下 3 層、地上 7 層之建築物，各層樓地板面積為 600 平方公尺，若地下 1 樓發生火警，則火警自動警報設…",{"webId":115,"number":116,"stem":117,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-023",23,"依各類場所消防安全設備設置標準，火警探測器之探測區域係指裝置面之四周以淨高 X 公分以上之樑或類似構造體區劃包圍者。…",{"webId":119,"number":120,"stem":121,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-024",24,"差動式分布型探測器採熱電偶式時，下列敘述何者錯誤？",{"webId":123,"number":12,"stem":124,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-025","下列有關火警受信總機之裝置規定，何者錯誤？",{"webId":126,"number":127,"stem":128,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-026",26,"對於單相交流 110 V 之緊急電源插座進行外觀及性能檢查時，下列何者與消防安全設備及必要檢修項目檢修基準之規定不同…",{"webId":130,"number":131,"stem":132,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-027",27,"依緊急廣播設備之揚聲器設置規定，廣播區域超過 100 平方公尺時，距揚聲器 1 公尺處所測得之音壓應為多少分貝以上？",{"webId":134,"number":135,"stem":136,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-028",28,"瓦斯漏氣火警自動警報設備進行性能檢查時，檢知區域警報裝置其音壓在距 1 公尺處應為多少分貝以上？",{"webId":138,"number":139,"stem":140,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-029",29,"有關瓦斯漏氣檢知器之設置，當瓦斯對空氣之比重小於 1 時，應設於距瓦斯燃燒器具水平距離 A 公尺以內；當瓦斯對空氣之…",{"webId":142,"number":143,"stem":144,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-030",30,"火警自動警報設備之緊急電源，其容量能使其有效動作 A 分鐘以上；緊急廣播設備之緊急電源，其容量能使其有效動作 B 分…",{"webId":146,"number":147,"stem":148,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-031",31,"一一九火災通報裝置，下列規定何者正確？",{"webId":150,"number":151,"stem":152,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-032",32,"下列有關得免設緊急照明設備之處所，何者錯誤？",{"webId":154,"number":155,"stem":156,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-033",33,"緩降機在進行綜合檢查之下降試驗時，以測量下降距離及下降時間計算出下降速度，平均下降速度何者正確？",{"webId":158,"number":159,"stem":160,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-034",34,"依消防安全設備及必要檢修項目檢修基準，救助袋進行開口部外觀檢查時，開口部面積之限制，下列何者正確？",{"webId":162,"number":163,"stem":164,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-035",35,"依各類場所消防安全設備設置標準規定，避難指標設於走廊或通道時，自走廊或通道任一點至指標之步行距離在多少公尺以下？",{"webId":166,"number":167,"stem":168,"answer":40,"indexable":27},"fire-110-1-alarm-evacuation-036",36,"某場所第五層需設置排煙設備，樓地板面積為 1200 平方公尺並區分為 450、400 及 350 平方公尺等三個防煙…",{"webId":170,"number":171,"stem":172,"answer":26,"indexable":27},"fire-110-1-alarm-evacuation-037",37,"下列有關緊急電源插座之設置，何者錯誤？",{"webId":174,"number":175,"stem":176,"answer":31,"indexable":27},"fire-110-1-alarm-evacuation-038",38,"特別安全梯排煙室設置直接面向戶外之窗戶時，窗戶之有效開口面積應在多少平方公尺以上？",{"webId":178,"number":179,"stem":180,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-039",39,"依消防安全設備及必要檢修項目檢修基準，火焰式探測器進行性能檢查時，使用火焰探測器用動作試驗器，探測器應在多少時間內動…",{"webId":182,"number":183,"stem":184,"answer":49,"indexable":27},"fire-110-1-alarm-evacuation-040",40,"避難器具之裝設規定，下列何者正確？",50,1785129961728]