[{"data":1,"prerenderedAt":186},["ShallowReactive",2],{"essay-alarm-evacuation-107-1":3},{"set":4,"subjectMeta":17,"mcq":22,"points":185},{"subject":5,"slug":6,"year":7,"session":8,"questions":9},"警報與避難系統消防安全設備概要","alarm-evacuation",107,1,[10,14],{"number":8,"text":11,"points":12,"imagesPending":13},"請依據「各類場所消防安全設備檢修及申報作業基準」，試述各類避難器具外觀檢查開口部時之檢查方法、判定方法及注意事項？（25 分）",25,false,{"number":15,"text":16,"points":12,"imagesPending":13},2,"桃園市某工廠發生大火，造成多名消防員殉職，公共危險物品安全管理議題再度被社會大眾重視，請依據「各類場所消防安全設備設置標準」，分別試述公共危險物品製造場所、一般處理場所、室內儲存場所及室內儲槽場所應設置火警自動警報設備之規定？（25 分）",{"name":5,"shortName":18,"slug":6,"fullName":5,"kicker":19,"tagline":20,"hint":21},"警報與避難系統","警報與避難 · Alarm & Egress","探測器、受信總機、緊急廣播,加上標示設備、緊急照明與避難器具——條號最零碎,也最吃「表格記憶」。","警報系統抓火警分區劃定原則、各型探測器(差動式局限型\u002F分布型、定溫式、偵煙式)的裝置場所與高度限制、受信總機與緊急電源;避難系統抓出口\u002F避難方向指示燈的設置與有效範圍、緊急照明照度、緩降機與避難器具的設置數量與開口面規定。條文以表格呈現者多,建議整理成對照表背。",[23,28,31,36,41,46,50,54,58,62,66,70,74,78,82,86,90,94,98,102,106,110,114,118,122,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181],{"webId":24,"number":8,"stem":25,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-001","依各類場所消防安全設備設置標準規定，除供甲類場所、地下建築物、高層建築物或應設置偵煙式探測器之場所外，若要以自動撒水…","B",true,{"webId":29,"number":15,"stem":30,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-002","差動式分布型探測器為熱半導體式時，裝接於一個檢出器之感熱器數量，下列何者正確？",{"webId":32,"number":33,"stem":34,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-003",3,"下列何者非屬定溫式探測器可裝設場所？","C",{"webId":37,"number":38,"stem":39,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-004",4,"下列那一種探測器，不可以裝設於室內天花板或屋頂板高度 15 公尺以上未滿 20 公尺之空間？","A",{"webId":42,"number":43,"stem":44,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-005",5,"有一地下三層地上十層之建築物，總樓地板面積 5000 平方公尺，若起火樓層位於三樓時，下列那一樓層火警自動警報設備須…","D",{"webId":47,"number":48,"stem":49,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-006",6,"下列何種使用瓦斯之場所，應設置瓦斯漏氣火警自動警報設備？",{"webId":51,"number":52,"stem":53,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-007",7,"有一防火構造建築物，其探測區域樓地板面積為 100 平方公尺，欲設置差動式分布型熱電偶式探測器，至少應該設置多少探測…",{"webId":55,"number":56,"stem":57,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-008",8,"當差動式分布型探測器為空氣管式時，下列那一項的敘述不符合設置標準？",{"webId":59,"number":60,"stem":61,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-009",9,"以下有關各類場所消防安全設備設置標準對火警分區的規定，何者錯誤？",{"webId":63,"number":64,"stem":65,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-010",10,"依各類場所消防安全設備設置標準第 23 條規定，各類場所均應設置避難指標。但設有以下那一個設備時，在其有效範圍內，得…",{"webId":67,"number":68,"stem":69,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-011",11,"依各類場所消防安全設備設置標準規定，火警受信總機、中繼器及偵煙式探測器，有設定蓄積時間時，其蓄積時間之合計，每一火警…",{"webId":71,"number":72,"stem":73,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-012",12,"有關光電式分離型探測器光軸，下列設置規定何者正確？",{"webId":75,"number":76,"stem":77,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-013",13,"依各類場所消防安全設備設置標準規定，火警自動警報設備之配線，除依屋內線路裝置規則外，其電源回路導線間及導線與大地間之…",{"webId":79,"number":80,"stem":81,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-014",14,"依各類場所消防安全設備設置標準規定，火警受信總機若為壁掛型，總機操作開關距離樓地板面之高度，應該為多少公尺範圍？",{"webId":83,"number":84,"stem":85,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-015",15,"有關緊急供電系統之電源，下列何者錯誤？",{"webId":87,"number":88,"stem":89,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-016",16,"避難器具之設置數量與場所之收容人數有很大的關係，依各類場所消防安全設備設置標準規定，有關醫療機構（醫院、診所）候診室…",{"webId":91,"number":92,"stem":93,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-017",17,"供緩降機或救助袋使用之支固器具及供懸吊型梯、滑杆或避難繩索使用之固定架，若使用螺栓固定時，下列何者錯誤？",{"webId":95,"number":96,"stem":97,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-018",18,"依各類場所消防安全設備設置標準規定，每一火警分區，依規定設置火警發信機，其標示燈應平時保持明亮，其透明罩為圓弧形，裝…",{"webId":99,"number":100,"stem":101,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-019",19,"在設置避難器具時，皆必須考慮其開口部保有必要開口面積、無操作障礙之面積、下降空間及下降空地等因素，試問於設置避難器具…",{"webId":103,"number":104,"stem":105,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-020",20,"依各類場所消防安全設備設置標準規定，瓦斯漏氣警報裝置之檢知器所能檢知瓦斯漏氣之區域內，該檢知器動作時，該區域內之檢知…",{"webId":107,"number":108,"stem":109,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-021",21,"依各類場所消防安全設備設置標準規定，緊急照明設備除內置蓄電池外，應連接緊急電源，其蓄電池容量應能使其持續動作 a 分…",{"webId":111,"number":112,"stem":113,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-022",22,"依各類場所消防安全設備設置標準規定，火警自動警報設備之緊急電源，應使用蓄電池設備，其容量能使其有效動作多少分鐘以上？",{"webId":115,"number":116,"stem":117,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-023",23,"自居室任一點易於觀察識別其主要出入口，且與主要出入口之步行距離符合規定者，得免設出口標示燈、避難方向指示燈或避難指標…",{"webId":119,"number":120,"stem":121,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-024",24,"P 型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，依各類場所消防安全設備設置標準規定，不得超過…",{"webId":123,"number":12,"stem":124,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-025","有一飯店，其三樓之樓地板面積為 1200 平方公尺，依各類場所消防安全設備設置標準規定，於設置出口標示燈時，除應使用…",{"webId":126,"number":127,"stem":128,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-026",26,"依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，有關電源回路之配線耐燃保護，若電線裝於…",{"webId":130,"number":131,"stem":132,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-027",27,"依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，緊急用電源回路及操作回路，應使用多少伏…",{"webId":134,"number":135,"stem":136,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-028",28,"依各類場所消防安全設備檢修及申報作業基準規定，對火警自動警報設備進行二信號性能檢查時，有關判定方法，下列敘述何者錯誤…",{"webId":138,"number":139,"stem":140,"answer":26,"indexable":27},"fire-107-1-alarm-evacuation-029",29,"依各類場所消防安全設備設置標準規定，有關標示設備之敘述，何者正確？",{"webId":142,"number":143,"stem":144,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-030",30,"偵煙式探測器除光電式分離型外，下列裝置規定何者錯誤？",{"webId":146,"number":147,"stem":148,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-031",31,"依各類場所消防安全設備設置標準規定，公共危險物品製造場所及一般處理場所總樓地板面積在多少平方公尺以上者，應設置火警自…",{"webId":150,"number":151,"stem":152,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-032",32,"依各類場所消防安全設備設置標準規定，下列何者非屬消防搶救上之必要設備種類？",{"webId":154,"number":155,"stem":156,"answer":40,"indexable":27},"fire-107-1-alarm-evacuation-033",33,"依各類場所消防安全設備檢修及申報作業基準規定，檢查檢知器時，使用「加瓦斯試驗器」進行加瓦斯測試，對空氣之比重未滿一者…",{"webId":158,"number":159,"stem":160,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-034",34,"依各類場所消防安全設備檢修及申報作業基準規定，緊急照明設備在建築物總樓地板面積為 5000 平方公尺時，檢查緊急電源…",{"webId":162,"number":163,"stem":164,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-035",35,"依各類場所消防安全設備檢修及申報作業基準規定，緊急電源插座為單相交流 110 V 者，應用額定 150 V， X 安…",{"webId":166,"number":167,"stem":168,"answer":45,"indexable":27},"fire-107-1-alarm-evacuation-036",36,"依各類場所消防安全設備設置標準規定，下列處所何者不得免設緊急照明設備？",{"webId":170,"number":171,"stem":172,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-037",37,"設置避難器具時，標示其設置位置、使用方法並設置指標，下列規定何者錯誤？",{"webId":174,"number":175,"stem":176,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-038",38,"依各類場所消防安全設備設置標準規定，差動式分布型及偵煙式探測器之探測區域，指探測器裝置面之四周以淨高多少公分以上之樑…",{"webId":178,"number":179,"stem":180,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-039",39,"依各類場所消防安全設備設置標準規定，緊急廣播設備之啟動裝置應符合 CNS 10522 之規定，且設在距樓地板高度 X…",{"webId":182,"number":183,"stem":184,"answer":35,"indexable":27},"fire-107-1-alarm-evacuation-040",40,"依各類場所消防安全設備檢修及申報作業基準規定，緩降機應以測量下降距離及下降時間，計算出下降速度，最大下降速度應在每秒…",50,1785129961799]